MONEL 400
Nickel-Copper Alloy. Values below are the requirements of the standard named beside them; the mill certificate governs the material delivered.
Designations
- UNS
- N04400
- EN number
- 2.4360
- EN name
- NiCu30Fe
Density
- Density
- 8800 kg/m³
- Per
- Special Metals / nickel alloy datasheets
- Corrosion resistance
- Very high
- Product forms
- Sheet, plate, bar, pipe
Chemical composition
| Standard | Product form | Basis | C | Si | Mn | S | Ni | Cu | Other rules |
|---|---|---|---|---|---|---|---|---|---|
| ASTM / Special Metals | Nickel-copper | Specification | ≤ 0.3 | ≤ 0.5 | ≤ 2 | ≤ 0.024 | ≥ 63 | 28–34 | Fe 1.0-2.5; Ni+Co 63 min |
mass %. A blank cell means the standard sets no requirement for that element, not zero. Single values are limits: "≤" a maximum, "≥" a minimum.
Reference values from the cited standards. They describe what the standard requires, not a specific heat of material; the mill test certificate governs what is delivered.
Mechanical properties
| Standard | Product form | Condition / temper | Test temperature | Yield | Tensile | Elongation min | Notes |
|---|---|---|---|---|---|---|---|
| ASTM B127/vendor reference | Plate/Sheet | Annealed | 20 °C | 0.2% offset ≥ 195 MPa | ≥ 485 MPa | 35 % (Product/condition dependent) | Representative annealed values; verify purchase specification. |
Each row is one standard, one product form and one condition — the values do not transfer across rows. A blank cell means the standard sets no requirement.
Reference values from the cited standards. They describe what the standard requires, not a specific heat of material; the mill test certificate governs what is delivered.
Physical properties
| Temperature | Density | Young’s modulus | Poisson’s ratio | Thermal expansion (20–100°C) | Thermal conductivity (20°C) | Specific heat | Electrical resistivity (20°C) | Melting range | Magnetic |
|---|---|---|---|---|---|---|---|---|---|
| 20 °C | 8800 kg/m³ | 179 GPa | 0.32 | 13.9 µm/m·°C | 21.8 W/m·K | 0.427 kJ/kg·°C | 0.51 µΩ·m | 1300–1350 °C | Slightly magnetic depending condition |
Reference values from the cited standards. They describe what the standard requires, not a specific heat of material; the mill test certificate governs what is delivered.
Typical applications
Marine, hydrofluoric acid, chemical
Approximate equivalents
Approximate equivalents: equivalents are a technical reference, not a substitution instruction, verify against project specification.
| Grade | Systems | Relationship | Note | Key difference |
|---|---|---|---|---|
| MONEL 400 | UNS/ASTM → EN | Same grade, another designation | Commonly cross-referenced nickel-copper alloy family. | Confirm product standard. Compared designation: 2.4360 / NiCu30Fe. |
Common questions
- 01What is the density of MONEL 400?
- 8800 kg/m³ — the figure the weight calculators on this site use for MONEL 400. The value is Special Metals / nickel alloy datasheets’s.
- 02What is the chemical composition of MONEL 400?
- C ≤ 0.3, Si ≤ 0.5, Mn ≤ 2, S ≤ 0.024, Ni ≥ 63, Cu 28–34, in mass %, to ASTM / Special Metals. An element the standard sets no requirement for is left blank here rather than written as zero.
- 03What are the mechanical properties of MONEL 400?
- Tensile ≥ 485 MPa, Yield ≥ 195 MPa, Elongation min ≥ 35 % — ASTM B127/vendor reference, Plate/Sheet, Annealed. Those are the standard’s requirements; the mill test certificate governs the metal delivered.
- 04What is MONEL 400 used for?
- Marine, hydrofluoric acid, chemical